Type T Details

Servotech has a large range of thermocouple extension cable. It is important that the correct cable is used to connect from the thermocouple
to the instrument, measuring point to ensure no loss of EMF signal.

Mild oxidising. Reducing vacuum or inert. Good where moisture is present. Low temperature and cryogenic applications.

TYPICAL CABLE SHEATH MATERIAL GUIDE

DETAILS
* OTHER TYPES MAY BE AVAILABLE UPON REQUEST
model Description Calibration Conductors insulation
WT21 Single pair, 260 Deg Cel ambient. General purpose. T 7 x 0.2 Teflon/Teflon
WT22 Single pair, 260 Deg Cel ambient. General purpose. T 1 x 0.3 Teflon/Teflon
WT24 Single pair, 215 Deg Cel ambient. Use in restricted spaces. T 1 x 0.5 Teflon/Teflon
WT26 Single pair, 260 Deg Cel ambient. General purpose used in harsh places. T 7 x 0.2 SS Overbraid/Teflon/Teflon
WT31 HKB T 14 x 0.2 M20 x 1.5