TYPE J Details

Servotech has a large range of thermocouple extension cable. It is important that the correct cable is used to connect from the thermocouple to the instrument measuring point to ensure no loss of EMF signal.

Clean oxidizing and inert. Limited use in vacuum or reducing. Wide temperature range. Most popular calibration.

TYPICAL CABLE SHEATH MATERIAL GUIDE

DETAILS
* OTHER TYPES MAY BE AVAILABLE UPON REQUEST
model Description Calibration Conductors insulation
WJ03 Single pair, 80 Deg Cel ambient. Cheap option for low temperatures, good with moisture. J 7 x 0.32 PVC/PVC
WJ04 Single pair, 105 Deg Cel ambient. Cheap option for low temperatures, good with moisture. J 7 x 0.32 PVC/PVC
WJ12 Single pair, 500 Deg Cel ambient. Used in harsh areas that require higher temperatures. Must be dry. J 7 x 0.2 SS Overbraid/Fibre Glass/Fibre Glass
WJ15 Single pair, 350 Deg Cel ambient. Used in higher temperatures. Must be dry. J 1 x 0.5 Fibre Glass/Fibre Glass
WJ16 Single pair, 350 Deg Cel ambient. Used in higher temperatures. Must be dry. J 7 x 0.2 Fibre Glass/Fibre Glass
WJ21 Single pair, 260 Deg Cel ambient. General purpose. J 7 x 0.2 Teflon/Teflon
WJ23 Single pair, 215 Deg Cel ambient. Used in restricted places. J 7 x 0.1 Teflon/Teflon
WJ26 Single pair, 260 Deg Cel ambient. General purpose used in harsh places. J 7 x 0.2 SS Overbraid/Teflon/Teflon
WJ27 Single pair, 260 Deg Cel ambient. Flexible and strong. Used in plastics industry. J 14 x 0.2 SS Overbraid/Teflon